NOTE: This article is for the SMART model thermostat, pictured here:

smart.png

To configure HVAC settings on the ecobee3, ecobee3 lite, or ecobee4, please refer to this article:
https://support.ecobee.com/hc/en-us/articles/360002020552

 

 

From the Home Screen, press Menu > Settings > Installation Settings > Thresholds > Advanced Settings


This section will allow you to customize how long each stage will run before the next stage will turn on. You may also program when a particular stage is turned on based on the temperature delta between the set temperature and the current temperature.


• Stage 1 Maximum Runtime: The maximum amount of time 1-stage will run before engaging the next stage. Options are Auto and 10-120 minutes


• Stage 1 Temperature Delta: The minimum difference between the current temperature and the set temperature that will activate this stage (regardless if the maximum run time of the previous stage was reached). Options are Auto and 1-10F.


• Comp to Aux Runtime: The maximum amount of time this stage will run before engaging the next stage. Options are Auto and 10-180 minutes


• Comp to Aux Temp Delta: The minimum difference between the current temperature and the set temperature that will activate this stage (regardless if the maximum run time of the previous stage was reached). Options are Auto and 1-10F.


• Cool Min On Time: Sets the minimum equipment run time in cool mode.


• Heat Min On Time: Sets the minimum equipment run time in heat mode.