Fast-Stat installation for heat-only systems

If your current thermostat only has 2 wires present and if your furnace/boiler has standard R, W, and C terminals, you can install the Fast-Stat Common Maker. The diagrams below illustrate how your system is currently wired vs. how it will be wired with the Fast-Stat.

 

Current thermostat wiring:

 

 

 

ecobee wiring with Fast-Stat:

If your current thermostat only has 2 wires present, your furnace/boiler has T&T contacts, and you're able to wire into your existing transformer, you can install the Fast-Stat Common Maker. The diagrams below illustrate how your system is currently wired vs. how it will be wired with the Fast-Stat.

You will need to splice the black wire coming from the Fast-Stat receiver into your C wire that's leading back to your transformer. If you have an actual C terminal, you will need to connect the black Fast-Stat wire to the C terminal.

 

Current thermostat wiring:

 

 

ecobee wiring with Fast-Stat:

If your current thermostat only has 2 wires present, your furnace/boiler has T&T or R and W contacts, and you're not able to wire into your existing transformer/don't have a C terminal, you can install the Fast-Stat Common Maker as well as an external 24V transformer. The diagrams below illustrate how your system is currently wired vs. how it will be wired with the Fast-Stat.

If you have an electrical outlet located near your furnace/boiler, you can use a 24V plugin wall transformer (easiest method). When installing an external 24V transformer, we recommend contacting a certified electrician to assist.

 

Current thermostat wiring:

 

 

ecobee wiring with Fast-Stat:

If your current thermostat only has 2 wires present and you're using a Taco zone board for zone control (you have multiple thermostats in your home), you can install the Fast-Stat Common Maker. The diagrams below illustrate how your system is currently wired with the Taco zone board vs. how it will be wired with the Taco zone board once the Fast-Stat is installed.

You will need to install a Fast-Stat for each thermostat/zone.

 

CM_Installation_-_Taco_Zone_Controller.PNG
If your current thermostat only has 2 wires present and you have Taco zone valves installed for zone control with your boiler, you can install the Fast-Stat Common Maker.

You will need to install a Fast-Stat for each thermostat/valve.

 

CM_Installation_-_Taco_3_wire_Zone_Valves_and_R-C-W_Boiler.PNG
If your current thermostat only has 2 wires present and you have Taco zone valves installed for zone control with your boiler, as well as a T&T Aquastat, you can install the Fast-Stat Common Maker.

 

If your current thermostat only has 2 wires present and you have Taco zone valves installed for zone control with your boiler, as well as a Z-TV-T Aquastat, you can install the Fast-Stat Common Maker.

 

CM_Installation_-_Taco_Zone_3_wire_Valves_with_Z-TV-T_Aquastat.PNG

 