EMS Specifications

Temperature Ranges

Heat: 45 – 79°F (7 – 26°C)

Cool: 58 – 92°F (14 – 33°C)

Display: 40 – 100°F (5 – 37°C)

Sensitivity: +/- 1°F (0.5°C)

Equipment Interface Operating: -40o to 160oF (-40o to 70oC)

Thermostat Operating: 32o to 130oF (0o to 55oC)

 

Humidity Range

Humidify: 20 to 50% R.H

Dehumidify: 30 to 60% R.H

Display: 0 - 90% R.H

Sensitivity: +/- 2% R.H.

Operating: 5 – 95% R.H non-condensing

 

Dimensions

Thermostat: 5.5”W x 3.25”H x 1”D (139.5mm H x 82.5mm W x 25mm D)

Equipment Interface: 4.6”W x 10”H x 1.3”D (118mm W x 254mm H x 32mm D)

 

Power

AC Transformer - 24 VAC - 3VA Minimum (not included)

Battery – CR2032 – 3V lithium coin cell (included),

Power Adaptor - #EB-PS-01 - 120V 50/60Hz to 12V DC 1A (not included)

Wiring Specifications

 Refer to this table to determine maximum wire lengths allowed:

 

Thermostat to Equipment Interface: 

           18 AWG                 20 AWG                  22 AWG

           1250ft/380m         790ft/240m            500ft/150m

 Equipment Interface to Heating/Air Equipment:

 

           18 AWG                 20 AWG                  22 AWG

           128ft/39m               80ft/24m                 50ft/15m